| | Print | |
What Are Double Lap Flares?Double-lap flares provide added-strength joints which are more resistant to fatigue and provide a better seal than single-thickness flares.Double Flaring Done RightDouble-lap flares formed by PHI machinery and tooling are free of cracks and pit marks. The joint is also designed so that the inside surface of the flare has a larger diameter than the inside diameter of the tube or pipe. As a result, the double lap flares will not interfere with flow characteristics of the system.Typical Applications of Double FlaringThe typical applications of double flaring include thin-wall tubing connections that are subject to shock, vibration or high internal pressures such as automobile brake lines and critical aircraft hydraulic lines.
Standard MS33583 Dimensions for 37 Degree Double-Flared Tubing
|
|||||||||||||||||||||||||||||||||||||||||||||||
| Nominal T-OD (Inches) | A-Dia. ±.005 (Inches) |
1/8 | .187 |
3/16 | .275 |
1/4 | .355 |
5/16 | .420 |
3/8 | .495 |
7/16 | .565 |
1/2 | .635 |